Preparation and cleaning
Use completely clean spray equipment. Rinse away cleaning solvents or thinners with water before applying the coating. Clean the roller with water after use and allow it to dry before reuse.

Koruflex is a blue or transparent water-based peelable coating for temporary protection of suitable non-porous surfaces. It is supplied ready to use and can be applied by airless spray or long-pile roller. Do not dilute it with water or thinner.

For airless spray, apply two passes, one vertical and one horizontal. The supplied technical data sheet indicates around 100–120 µm dry film thickness and approximately 3.5–4 m² coverage per kg under the described spray method.
For roller application, use a dry long-pile roller. Allow the first coat to dry before applying the second. Two coats give an average dry film thickness of 80–100 µm according to the supplied technical data sheet.
Apply above 5°C. Drying at room temperature is approximately 2–3 hours and varies with heat and air circulation. The data sheet specifies peeling between 8°C and 30°C.
The coating is supplied in 15 kg buckets. Protect it from freezing during storage. Consult the safety data sheet and use a mask for airless spraying.
These values come from the supplied KORUFLEX technical data sheet. They describe KORUFLEX; a separate KORUFLEX ADV technical sheet was not supplied.
| Item | Data sheet guidance |
|---|---|
| Product | Water-based blue or transparent peelable coating; ready to use. Do not dilute with water or thinner. |
| Methods | Airless spray or long-pile roller. |
| Spray hose internal diameter | 13 mm |
| Spray nozzle diameter | 2.8 mm |
| Fluid pressure | 2.5 bar |
| Air pressure | 4.5 bar |
| Spray passes | Two passes, one vertical and one horizontal; the first pass need not dry before the second. |
| Spray dry film thickness | Approximately 100–120 µm after the described double pass. |
| Spray coverage | Approximately 3.5–4 m²/kg under the described method; spray consumption is higher than roller consumption. |
| Roller | Use a dry long-pile roller. Apply two coats, allowing the first coat to dry before the second. |
| Roller dry film thickness | Approximately 80–100 µm for two coats. |
| Application temperature | Do not apply below 5°C. |
| Drying time | Approximately 2–3 hours at room temperature; higher temperature and good air circulation may shorten it. |
| Peeling temperature | 8–30°C, as stated in the data sheet. |
| Packaging | 15 kg per bucket. |
| Storage | Avoid freezing. |
Use completely clean spray equipment. Rinse away cleaning solvents or thinners with water before applying the coating. Clean the roller with water after use and allow it to dry before reuse.
Avoid continuous skin contact. Wear a mask while airless spraying. If the product contacts the eyes, rinse with water. Consult the material safety data sheet for further detail; it was not included in the supplied archive.
The data sheet describes protection against dirt, overpainting, scratches, welding spatters, water, humidity and corrosion. Confirm suitability using the product-specific surface chart and test conditional surfaces before wider use.